Medical Device Software Development for SaMD and Connected Devices

Device software is judged by its evidence as much as its code. We engineer SaMD and connected device software with the lifecycle, risk, and cybersecurity documentation regulators expect.

Medical device software: overview

Medical device software differs from other healthcare software in one fundamental way: the development process itself is regulated. Requirements, architecture, verification, risk controls, and changes must be traceable and documented. Teams that build first and document later usually discover that their test evidence does not trace to requirements, that risk controls were never verified, or that a SOUP library has no documented rationale. Fixing that before a submission costs months.

IEC 62304 defines the software lifecycle processes, scaled by software safety class. ISO 14971 defines risk management across the device. FDA recognizes both as consensus standards. Since February 2, 2026, FDA's Quality Management System Regulation, the amended 21 CFR Part 820, incorporates ISO 13485:2016 by reference, which brings US quality system expectations closer to international practice. We engineer within your QMS, producing artifacts that fit your design controls rather than parallel paperwork.

Connected devices bring cybersecurity obligations. Section 524B of the FD&C Act requires submissions for cyber devices to include a plan for monitoring and addressing postmarket vulnerabilities, processes that provide reasonable assurance of cybersecurity, and a software bill of materials. FDA's premarket cybersecurity guidance describes expected threat modeling, security architecture views, and testing. We build these into the architecture and pipeline so evidence is produced continuously.

Engineering challenges in medical device software

  • 01Traceability gaps

    Requirements, risk controls, design elements, and tests drift apart in separate tools. Gaps surface during submission preparation or audits, when they are most expensive to close.

  • 02Safety classification decisions

    Software safety class drives the rigor of IEC 62304 activities. Classifying too low creates audit findings; too high adds unnecessary overhead. Architecture segregation can legitimately change classes for some components.

  • 03SOUP and open source management

    Every third-party library needs identification, requirements, risk assessment, and monitoring for anomalies and vulnerabilities, which overlaps with SBOM obligations.

  • 04Cybersecurity across the lifecycle

    Threat models, penetration testing, vulnerability handling, and patching plans must exist before submission and continue after release.

  • 05Agile within design controls

    Sprints and continuous integration work in regulated development, but only when design reviews, verification, and change control are mapped deliberately onto the cadence.

Technical capabilities

What our medical device software work covers

  • IEC 62304 lifecycle implementation

    Software development plans, requirements, architecture, detailed design, unit and integration verification, and release processes scaled to safety class and integrated with your QMS.

  • ISO 14971 risk management support

    Hazard analysis, software contribution to hazardous situations, risk control implementation, and verification of control effectiveness traced in the risk file.

  • Cybersecurity engineering

    Threat modeling, security architecture views, SBOM generation, vulnerability monitoring, and penetration test coordination aligned with FDA premarket cybersecurity guidance and section 524B.

  • Traceability tooling

    Linked requirements, risks, code, and tests in tools such as Jama, Polarion, or Git-based traceability, with automated trace reports for design reviews.

  • Verification automation

    Automated unit, integration, and system tests with recorded evidence, plus hardware-in-the-loop setups for embedded components.

  • SaMD cloud and mobile engineering

    Cloud backends and mobile apps for device software functions, with controlled deployment, version pinning, and postmarket monitoring.

  • Submission documentation support

    Software documentation for premarket submissions following FDA's device software functions guidance, prepared with your regulatory team.

Software architecture

Reference architecture for medical device software

Device software architecture segregates safety-relevant components, isolates security boundaries, and makes every release reproducible from versioned artifacts.

  1. User interfaces
    • Clinician app
    • Patient app
    • Device UI
  2. Device software functions
    • Algorithm module
    • Alarm logic
    • Data validation
  3. Platform services
    • Secure update
    • Device identity
    • Logging & telemetry
  4. Connectivity
    • BLE / cellular
    • Cloud API
    • EHR interfaces
  5. Lifecycle evidence
    • Trace matrix
    • SBOM
    • Risk file
    • Test records
Illustrative layering; actual architecture is decided per engagement and documented in decision records.

Technology stack for medical device software

Embedded
C / C++Rust where qualifiedFreeRTOS or Zephyr
SaMD and cloud
Python, Java, or TypeScript servicesContainerized deploymentsInfrastructure as code
Mobile
Swift / KotlinBLE stacks
Quality tooling
Jama, Polarion, or Git-based ALMStatic analysis (e.g., MISRA checkers)Coverage tools
Security
SBOM tools (CycloneDX, SPDX)Vulnerability scanningCode signing / HSM

Security & compliance

Security and compliance considerations for medical device software

What regulations require

  • Section 524B of the FD&C Act requires premarket submissions for cyber devices to include a plan to monitor, identify, and address postmarket cybersecurity vulnerabilities, processes providing reasonable assurance of cybersecurity, and a software bill of materials.
  • FDA's Quality Management System Regulation (amended 21 CFR Part 820), effective February 2, 2026, incorporates ISO 13485:2016 by reference.
  • FDA recognizes IEC 62304 (software lifecycle) and ISO 14971 (risk management) as consensus standards that manufacturers can use to support submissions.
  • Software that meets the device definition in section 201(h) of the FD&C Act is regulated by FDA; some functions are excluded under section 520(o).

Recommended engineering practices

  • Threat-model early and update the model with each architectural change.
  • Generate SBOMs in the build pipeline and monitor components for new vulnerabilities.
  • Sign firmware and software updates and verify signatures on the device.
  • Segregate safety-critical components to contain failures and simplify classification.
  • Keep a coordinated vulnerability disclosure process and patch plan ready before launch.

Regulatory summaries are educational, not legal advice. HIPAA compliance is an organizational program; software can support safeguards but cannot by itself make an organization compliant. Systems that handle PHI need their own risk analysis, vendor evaluation, and Business Associate Agreements before deployment.

Integration capabilities

Integrations we engineer for medical device software

  • BLE and cellular device connectivity
  • Cloud device management
  • FHIR and HL7 v2 EHR interfaces
  • IEEE 11073 device standards where applicable
  • ALM and requirements tools
  • Vulnerability databases
  • Postmarket complaint and CAPA systems

Engineering methodology

How we approach medical device software

  1. 1

    Intended use and classification

    With your regulatory team, we confirm intended use, device classification, and software safety class.

  2. 2

    Planning within the QMS

    Software development, risk management, and cybersecurity plans are written to fit your QMS procedures.

  3. 3

    Iterative design and verification

    Sprints produce requirements, design, code, and verification evidence together, with design reviews at defined milestones.

  4. 4

    System verification and security testing

    Integrated system testing, penetration testing, and residual risk evaluation are completed and documented.

  5. 5

    Release and postmarket

    Controlled release, SBOM publication, vulnerability monitoring, and change control for updates.

Business use cases

Where medical device software delivers value

  • SaMD algorithm platform

    A cloud-hosted analysis function with versioned algorithms, traceable verification, and controlled rollout.

  • Connected wearable

    Firmware, mobile companion app, and cloud backend for a monitoring wearable with secure updates.

  • Legacy device remediation

    Bringing documentation, SBOMs, and cybersecurity controls up to current expectations for a marketed device.

  • Device data integration

    Integrating device outputs into EHRs while keeping device functions separated from non-device software.

Technical comparison

IEC 62304 software safety classes
ClassPossible harmImplication for rigor
Class ANo injury or damage to health is possibleLightest documentation and verification requirements
Class BNon-serious injury is possibleArchitecture and unit verification required
Class CDeath or serious injury is possibleMost rigorous, including detailed design and unit-level verification

Typical deliverables

What a medical device software engagement produces

  • Software development and maintenance plans
  • Requirements, architecture, and design documentation
  • Traceability matrix
  • Risk management inputs and control verification records
  • Threat model, security architecture views, and SBOM
  • Verification and validation evidence
  • Cybersecurity postmarket management plan inputs

Device software submission readiness

  • Intended use and software safety class documented
  • Requirements traced to design, code, tests, and risk controls
  • SOUP list with rationale and anomaly review
  • SBOM generated and maintained
  • Threat model and security testing completed
  • Postmarket vulnerability plan in place
  • Design reviews recorded in the QMS

Cost and timeline factors

What shapes medical device software cost and timeline

  • Software safety class and device classification
  • Embedded versus cloud or mobile SaMD
  • Maturity of your existing QMS
  • Cybersecurity scope and cyber device status
  • Number of platforms and integrations
  • Remediation of existing undocumented software

Typical timeline

A lower-risk SaMD function within an established QMS can reach submission readiness in several quarters. Higher-class embedded systems or devices requiring extensive cybersecurity work take longer.

Read the cost guide

Medical device software FAQs

What changed with FDA's QMSR in 2026?

FDA's Quality Management System Regulation took effect February 2, 2026, amending 21 CFR Part 820 to incorporate ISO 13485:2016 by reference. Manufacturers already aligned with ISO 13485 should find the requirements familiar, though FDA-specific provisions remain. Review your QMS procedures with your regulatory team to confirm alignment.

What is a cyber device under section 524B?

Section 524B applies to devices that include software, can connect to the internet, and could be vulnerable to cybersecurity threats. Submissions for these devices must include a postmarket vulnerability plan, processes providing reasonable assurance of cybersecurity, and an SBOM. FDA's premarket cybersecurity guidance explains the documentation it expects.

Can we use agile development for medical device software?

Yes. IEC 62304 does not prescribe a waterfall model. Agile works when design inputs, reviews, verification, and change control are mapped onto the iteration cadence and evidence is captured continuously. AAMI TIR45 provides guidance on applying agile practices to medical device software.

Do you handle FDA submissions?

We prepare software and cybersecurity documentation and evidence for your regulatory team, who own the submission and FDA interactions. We do not claim FDA clearances or approvals on your behalf. Engaging regulatory expertise early helps align engineering artifacts with the chosen pathway.

Discuss your healthcare engineering project

Tell us about the system, the integrations it depends on, and the constraints you are working within. A senior engineer will review it and reply with questions, not a sales script.