Skip to content
Healthcare SoftwareEngineering

Interoperability

Healthcare Data Interoperability Engineering

Moving data is the easy half. We engineer the other half: making a lab result, diagnosis, or medication from one system mean the same thing in another.

Data interoperability: overview

Interoperability has layers. Foundational interoperability is getting bytes from one system to another. Structural interoperability is agreeing on format, such as HL7 v2, C-CDA, or FHIR. Semantic interoperability is agreeing on meaning, which requires shared terminologies: LOINC for lab tests and observations, SNOMED CT for clinical findings and problems, RxNorm for medications, ICD-10-CM for diagnosis coding, and CPT for procedures. CPT is maintained and licensed by the American Medical Association, so any product that stores or displays it needs a license.

The United States Core Data for Interoperability (USCDI) defines the data classes and elements that certified health IT must support, and US Core maps them to FHIR profiles. USCDI expands in versions over time, and certification requirements reference specific versions on a schedule set by ONC (now ASTP/ONC). When a health system asks for a feed or API to be USCDI-aligned, they mean these data elements, coded to the vocabularies USCDI specifies, not just valid JSON.

Most organizations hold a mix of sources: v2 feeds with local lab codes, C-CDA documents from referrals and HIEs, FHIR APIs from newer systems, and claims data with ICD-10-CM and CPT. We build pipelines that normalize those sources into a consistent, provenance-tagged model, map local codes to standard vocabularies with human review for ambiguous cases, and resolve patient identity across facilities. The result is data that analytics, AI, and clinical applications can trust.

Engineering challenges in data interoperability

  • 01Local codes everywhere

    Lab systems use local test codes, and many have never been mapped to LOINC. A glucose result might appear under dozens of local codes across a network.

  • 02Document-centric exchange

    C-CDA documents carry valuable data, but discrete entries may be sparse, duplicated, or inconsistent with the narrative. Extraction needs reconciliation rules.

  • 03Patient matching

    There is no national patient identifier in the US. Matching across organizations depends on demographics, which contain typos, changes, and shared values within families.

  • 04Terminology licensing and versions

    SNOMED CT use in the US is covered through the UMLS license, CPT requires an AMA license, and every vocabulary releases updates that change mappings over time.

  • 05Provenance loss

    Once data from multiple sources is merged, it is easy to lose track of where a value came from, which undermines clinical trust and audit.

Technical capabilities

What our data interoperability work covers

  • Terminology mapping

    Mapping local codes to LOINC, SNOMED CT, RxNorm, and ICD-10-CM with automated candidate suggestions and clinician or informaticist review for low-confidence matches.

  • Terminology services

    FHIR terminology server setup for ValueSet expansion, ConceptMap translation, and version management across vocabulary releases.

  • C-CDA processing

    Parsing CCD, Discharge Summary, Referral Note, Progress Note, and other C-CDA document types into discrete data, and converting to FHIR with documented mapping rules.

  • Identity resolution

    Master patient index design using deterministic and probabilistic matching, with configurable thresholds, a manual review queue, and merge/unmerge history.

  • IHE-based exchange

    Integration with XDS.b document registries and repositories, PIX and PDQ identity services, and XCA-based networks used by HIEs and national frameworks.

  • USCDI gap analysis

    Assessment of which USCDI data elements your system captures, how they are coded, and what changes are needed for a target USCDI version.

  • Provenance and lineage

    Tagging every normalized record with source system, original code, transformation version, and timestamp, using FHIR Provenance where appropriate.

Software architecture

Reference architecture for data interoperability

A normalization pipeline turns structurally diverse inputs into a semantically consistent store while keeping the originals.

  1. Sources
    • HL7 v2 feeds
    • C-CDA documents
    • FHIR APIs
    • Claims files
  2. Structural conversion
    • v2 parser
    • C-CDA parser
    • FHIR ingestion
    • Raw archive
  3. Semantic normalization
    • Terminology server
    • Code mapping
    • Unit normalization
    • Review queue
  4. Identity
    • MPI
    • PIX/PDQ
    • Match review
  5. Consumption
    • FHIR API
    • Analytics warehouse
    • AI feature store
Illustrative layering; actual architecture is decided per engagement and documented in decision records.

Technology stack for data interoperability

Terminologies
LOINCSNOMED CT (via UMLS in the US)RxNormICD-10-CMCPT (AMA-licensed)
Standards
USCDIUS CoreC-CDA R2.1IHE XDS.b, PIX, PDQ, XCAFHIR R4
Tools
HAPI FHIR terminologySnowstormUMLS APIsMatching libraries
Data platform
PostgreSQLLakehouse storagedbtApache Spark

Security & compliance

Security and compliance considerations for data interoperability

What regulations require

  • ONC information blocking rules (45 CFR Part 171) define electronic health information broadly and require actors to avoid practices that interfere with its access, exchange, or use unless an exception applies.
  • Certified health IT must support USCDI data elements through the criteria that reference it, including the standardized API at 45 CFR 170.315(g)(10), on timelines set by ONC rulemaking.
  • Data de-identified under the HIPAA Privacy Rule's Safe Harbor or Expert Determination methods (45 CFR 164.514(b)) is no longer PHI, but re-identification risk should be reassessed when datasets are combined.

Recommended engineering practices

  • Keep original source codes alongside mapped standard codes so mappings can be audited and corrected.
  • Version terminology releases and re-run mappings when vocabularies update.
  • Require human review for low-confidence code and identity matches before they affect clinical views.
  • Track terminology license obligations in your dependency register.
  • Restrict MPI review tools to trained staff and log every merge decision.

Regulatory summaries are educational, not legal advice. HIPAA compliance is an organizational program; software can support safeguards but cannot by itself make an organization compliant. Systems that handle PHI need their own risk analysis, vendor evaluation, and Business Associate Agreements before deployment.

Integration capabilities

Integrations we engineer for data interoperability

  • Regional and state HIEs
  • IHE XDS.b registries and repositories
  • PIX/PDQ identity services
  • Carequality and CommonWell-connected networks
  • TEFCA QHINs
  • EHR FHIR APIs
  • Lab and claims data feeds
  • UMLS terminology services

Engineering methodology

How we approach data interoperability

  1. 1

    Source profiling

    We sample each source to measure code coverage, local code usage, missing fields, and identity quality.

  2. 2

    Target model and vocabulary choice

    We define the target model, often FHIR-based, and the vocabulary required for each data element.

  3. 3

    Mapping and review

    Automated mapping produces candidates; informaticists review edge cases, and decisions are stored as ConceptMaps.

  4. 4

    Pipeline build

    Conversion, normalization, and identity resolution run in versioned pipelines with data quality checks.

  5. 5

    Quality monitoring

    Dashboards track unmapped codes, match rates, and source drift, with alerts on regressions.

Business use cases

Where data interoperability delivers value

  • Network lab normalization

    A health system maps local lab codes from several hospitals to LOINC so quality measures compute consistently.

  • HIE document ingestion

    A care management platform extracts problems, medications, and allergies from incoming CCDs into discrete records with reconciliation.

  • Enterprise MPI

    A newly merged health system consolidates patient identities across two EHRs with a review queue for uncertain matches.

  • USCDI readiness

    A health IT developer identifies data elements missing for the next USCDI version required by certification.

Technical comparison

Core US healthcare terminologies
TerminologyDomainMaintainerLicensing note
LOINCLab tests, observations, document typesRegenstrief InstituteFree with license agreement
SNOMED CTClinical findings, problems, proceduresSNOMED International (US edition via NLM)US use through UMLS license
RxNormClinical drugsNational Library of MedicineFree; some source vocabularies restricted
ICD-10-CMDiagnosis codingCDC NCHS (US clinical modification)Public domain in the US
CPTProcedures and services billingAmerican Medical AssociationRequires AMA license

Typical deliverables

What a data interoperability engagement produces

  • Source data profiles
  • Target data model and vocabulary bindings
  • Terminology mappings as versioned ConceptMaps
  • Normalization and conversion pipelines
  • MPI configuration and match rules
  • USCDI gap analysis
  • Data quality dashboards

Semantic interoperability checklist

  • Every coded field has a target vocabulary
  • Original source codes are retained
  • Low-confidence mappings go to human review
  • Terminology versions tracked and updates scheduled
  • CPT license in place if CPT codes are stored or displayed
  • Identity match thresholds documented and monitored
  • Provenance recorded for merged records

Cost and timeline factors

What shapes data interoperability cost and timeline

  • Number and diversity of sources
  • Volume of local codes needing mapping
  • Clinical review capacity
  • Identity matching complexity
  • Terminology licensing
  • Target standards and certification needs

Typical timeline

Profiling and a mapping plan for a few sources typically take weeks. Full normalization pipelines with an MPI and ongoing mapping governance usually run over multiple quarters, since clinical review is a recurring effort rather than a one-time task.

Read the cost guide

Data interoperability FAQs

What is semantic interoperability in healthcare?

Semantic interoperability means two systems interpret exchanged data the same way. It depends on shared terminologies such as LOINC, SNOMED CT, and RxNorm, consistent units, and agreed data models. A valid FHIR message with a local lab code is structurally interoperable but not semantically interoperable until the code is mapped.

What is USCDI?

The United States Core Data for Interoperability is a standardized set of health data classes and elements, such as allergies, medications, lab results, and clinical notes, published by ONC. Certified health IT must support specified USCDI versions, and US Core maps those elements to FHIR profiles.

Do we need a license to use CPT codes?

Yes, in most cases. CPT is developed and copyrighted by the American Medical Association, and storing, displaying, or distributing CPT codes and descriptors in software generally requires an AMA license. Check your use case with the AMA. Other vocabularies like ICD-10-CM and LOINC have different, often free, terms.

How do IHE PIX and PDQ help with patient matching?

PIX (Patient Identifier Cross-referencing) links identifiers for the same patient across domains, so one system can find another's ID for a patient. PDQ (Patient Demographics Query) lets a system search for patients by demographics. FHIR-based versions, PIXm and PDQm, offer the same functions over REST.

Discuss your healthcare engineering project

Tell us about the system, the integrations it depends on, and the constraints you are working within. A senior engineer will review it and reply with questions, not a sales script.