AI Governance
Healthcare AI Governance That Works Beyond the Policy Document
A governance policy nobody can operationalize is a liability with a cover page. We help healthcare organizations build the inventory, risk tiers, review workflows, and evidence trails that turn an AI policy into decisions people can trace.
At a glance
- Standards & integrations
- Procurement and vendor management systemsCI/CD release pipelinesModel registriesAI monitoring and alertingIncident and patient safety reportingGRC platforms
- Typical deliverables
AI system inventory and intake process
Risk tiering criteria with worked examples
Evidence requirements and templates per tier
Committee workflow configuration
AI governance: overview
Most health systems and healthcare technology companies now have an AI policy. Fewer can answer basic questions from it: how many AI-enabled tools are in use, which ones touch clinical decisions, who approved each, what evidence they reviewed, and when each was last re-assessed. Governance fails at that operational layer, where the policy meets procurement, product releases, EHR vendor features switched on by default, and departmental tools nobody registered.
Our governance work is engineering-led. We build the AI system inventory as a maintained data asset rather than a spreadsheet, with intake forms connected to procurement and release processes so new systems are captured when they arrive. We define risk tiers based on intended use, autonomy, patient impact, and data sensitivity, and we tie each tier to specific required evidence: evaluation results, subgroup analysis, human oversight design, monitoring plans, and vendor documentation.
Frameworks provide structure. NIST AI RMF 1.0 organizes activities into Govern, Map, Measure, and Manage functions, and its Generative AI Profile adds risks specific to generative systems. Regulations add specific obligations, such as Section 1557 duties around patient care decision support tools and HTI-1 transparency for certified health IT. We map your process to those references so that the committee can see which obligations each review step addresses, without pretending a framework mapping equals compliance.
Engineering challenges in AI governance
01Shadow AI and vendor features
AI arrives through EHR upgrades, SaaS feature releases, and browser tools as often as through formal projects. Inventories built from project lists miss most of it.
02One review process for every risk level
Sending a meeting-notes summarizer through the same committee review as a sepsis alert either overwhelms the committee or encourages people to avoid it. Proportionate tiers are essential.
03Approval without evidence
Committees often approve tools based on vendor presentations. Without defined evidence requirements per tier, there is nothing to compare against when performance is questioned later.
04No re-review trigger
A model approved two years ago may have been retrained, re-prompted, or applied to a new population. Governance needs triggers based on changes and monitoring signals, not only calendar dates.
05Evidence scattered across tools
Evaluation reports in one place, committee minutes in another, monitoring dashboards somewhere else. When an auditor or patient asks, reconstructing the decision trail takes weeks.
Technical capabilities
What our AI governance work covers
AI system inventory
We design and build an inventory with structured fields for intended use, owner, vendor, model type, data used, risk tier, approval status, and monitoring links, fed by procurement and release intake.
Risk tiering model
We define tiers using criteria such as whether outputs influence clinical decisions, degree of autonomy, patient population, PHI use, and reversibility, with examples so requesters can self-classify consistently.
Tier-based evidence requirements
Each tier specifies the evaluation, subgroup analysis, human oversight design, monitoring plan, and vendor documentation required before approval and at re-review.
Committee workflow tooling
Intake, triage, review assignments, decisions, conditions, and expiry dates are tracked in a workflow system, so every decision has a record linked to the evidence considered.
Section 1557 decision support tool review
We help covered entities identify patient care decision support tools that use protected characteristics as inputs and document mitigation steps, as 45 CFR 92.210 requires reasonable efforts to do.
Framework mapping
We map your governance activities to NIST AI RMF 1.0 functions and the NIST AI 600-1 Generative AI Profile, and show where HTI-1 DSI source attributes or FDA considerations apply.
Change and incident triggers
Integration with model registries and monitoring systems raises re-review tasks when a model version changes, a monitored metric crosses a threshold, or an incident is reported.
Software architecture
Reference architecture for AI governance
Governance becomes operational when it is wired into the systems where AI changes happen: procurement, release pipelines, model registries, and monitoring.
- Intake
- Procurement intake
- Release pipeline hook
- Self-registration form
- Inventory
- AI system records
- Risk tier
- Owner and vendor
- Data use
- Review
- Evidence checklist
- Committee workflow
- Decision record
- Conditions and expiry
- Signals
- Model registry events
- Monitoring alerts
- Incident reports
- Reporting
- Board summaries
- Audit evidence packages
- Framework mapping
Technology stack for AI governance
- Workflow
- GRC platformsTicketing and workflow toolsCustom intake apps
- Inventory
- Relational databaseData catalog integrationAPI for system registration
- Integrations
- Model registry webhooksMonitoring alert routingProcurement system
- Documentation
- Model cardsSource attribute templatesEvidence repositories
- Reporting
- BI dashboardsExportable evidence packages
Security & compliance
Security and compliance considerations for AI governance
What regulations require
- HHS's Section 1557 final rule (45 CFR 92.210) prohibits covered entities from discriminating through patient care decision support tools and requires reasonable efforts to identify tools using race, color, national origin, sex, age, or disability as inputs and to mitigate discrimination risk; parts of the 2024 rule have been subject to litigation, so confirm current status with counsel.
- ONC's HTI-1 final rule created the decision support interventions criterion (45 CFR 170.315(b)(11)) for certified health IT, including source attributes for predictive DSIs and intervention risk management; health systems using certified EHRs can request this information from developers, and later rulemaking may revise these requirements.
- FDA's Predetermined Change Control Plan guidance for AI-enabled device software functions, finalized in December 2024, describes how manufacturers can specify planned model modifications in a marketing submission; governance processes should know which inventoried systems are FDA-regulated devices and whether they have an authorized PCCP.
- NIST AI RMF 1.0 (January 2023) and the Generative AI Profile (NIST AI 600-1, July 2024) are voluntary frameworks, not regulations, but are widely used to structure AI risk management programs.
Recommended engineering practices
- Scale review depth to risk tier so the committee spends its time on systems that influence clinical decisions.
- Require a named business owner and technical owner for every inventoried AI system.
- Set approval expiry dates and re-review triggers tied to model changes and monitoring signals.
- Ask vendors for model documentation, evaluation methods, and update notification commitments in contracts.
- Keep decision records and evidence together so any approval can be reconstructed.
- Include patient-facing transparency decisions, such as when to disclose AI use, in the review checklist.
Regulatory summaries are educational, not legal advice. HIPAA compliance is an organizational program; software can support safeguards but cannot by itself make an organization compliant. Systems that handle PHI need their own risk analysis, vendor evaluation, and Business Associate Agreements before deployment.
Integration capabilities
Integrations we engineer for AI governance
- Procurement and vendor management systems
- CI/CD release pipelines
- Model registries
- AI monitoring and alerting
- Incident and patient safety reporting
- GRC platforms
- EHR vendor DSI source attribute documentation
Engineering methodology
How we approach AI governance
- 1
Discover
Build the initial inventory from procurement records, EHR feature lists, network traffic to model providers, and department surveys.
- 2
Tier
Define risk tiers with examples and classify the discovered systems, focusing first on those influencing clinical decisions.
- 3
Define evidence
Specify required evidence per tier and create templates for evaluation summaries, oversight design, and monitoring plans.
- 4
Operationalize
Implement intake hooks, committee workflow, and change triggers in the tools people already use.
- 5
Report and refine
Produce regular reports for leadership, review cycle times, and adjust tiers and evidence where the process creates friction without reducing risk.
Business use cases
Where AI governance delivers value
Health system AI oversight program
Stand up an inventory, tiering, and committee workflow covering vendor and internally built AI across clinical and administrative areas.
Section 1557 tool review
Identify decision support tools that use protected characteristics as inputs and document the mitigation decision for each.
Vendor AI due diligence
Create a standard questionnaire and evidence checklist for evaluating AI features offered by EHR and SaaS vendors.
Governance for a healthcare AI product company
Build internal release governance that produces customer-ready documentation and supports customers' own governance reviews.
Technical comparison
| Tier | Example system | Evidence before approval |
|---|---|---|
| Low | Internal meeting summarizer, no PHI | Registration, data-use attestation |
| Moderate | Fax classifier routing documents | Evaluation results, exception handling, monitoring plan |
| High | Patient message reply drafts | Faithfulness testing, reviewer workflow, subgroup review |
| Highest | Clinical risk score shown to clinicians | Temporal and subgroup validation, regulatory analysis, 1557 review |
Typical deliverables
What a AI governance engagement produces
- AI system inventory and intake process
- Risk tiering criteria with worked examples
- Evidence requirements and templates per tier
- Committee workflow configuration
- NIST AI RMF and regulatory mapping
- Change and monitoring re-review triggers
- Leadership reporting dashboard
Signs your AI governance is operational
- You can list every AI-enabled system in use with its owner
- Each system has a risk tier assigned with stated criteria
- Approvals reference stored evidence, not just slides
- Approvals expire and changes trigger re-review
- Decision support tools using protected characteristics are identified
- Monitoring alerts route to the governance workflow
Cost and timeline factors
What shapes AI governance cost and timeline
- Size and spread of the existing AI footprint
- Whether workflow tooling exists or must be built
- Number of intake channels to connect
- Depth of regulatory mapping required
- Volume of systems needing initial review
- Integration with model registries and monitoring
Typical timeline
An initial inventory, tiering model, and committee workflow can usually be established within one quarter. Integrating intake with procurement and release pipelines and clearing the backlog of existing systems typically continues through the following two or three quarters.
Read the cost guideAI governance FAQs
What is healthcare AI governance?
Healthcare AI governance is the set of policies, roles, processes, and records an organization uses to decide which AI systems to use, under what conditions, and how to oversee them over time. In practice it includes an AI inventory, risk tiers, evidence requirements, a review committee, re-review triggers, and reporting, mapped to frameworks like NIST AI RMF and applicable regulations.
Which regulations apply to AI governance in US healthcare?
Several apply depending on the system and organization. HIPAA governs PHI. Section 1557 at 45 CFR 92.210 addresses discrimination through patient care decision support tools. ONC's HTI-1 sets DSI transparency requirements for certified health IT. FDA regulates AI that meets the device definition. NIST AI RMF is voluntary but widely used as structure.
How should AI systems be risk tiered?
Common criteria include whether outputs influence clinical decisions, how much autonomy the system has, whether a human reviews outputs, the patient population affected, use of PHI, and whether errors are reversible. Each tier should map to specific required evidence. Worked examples help requesters classify consistently, and the committee should be able to override.
How is governance different from AI monitoring?
Governance decides whether and under what conditions a system may be used and keeps the record of those decisions. Monitoring measures how the system behaves in production. The two connect: monitoring thresholds should be conditions of approval, and alerts that cross them should trigger governance re-review.
Related engineering topics
- Healthcare AI MonitoringProduction monitoring for healthcare AI: input drift, output quality, safety signals, override rates, and alert routing to owners.Read more
- Healthcare AI Model EvaluationEvaluation methodology for healthcare AI: reference datasets, rubrics, subgroup analysis, regression gates, and continuous re-evaluation.Read more
- Clinical Decision SupportEngineering CDS systems with transparent logic, CDS Hooks and SMART integration, and regulatory scoping against FDA's CDS criteria.Read more
- Healthcare AI Engineering GuideHow to take healthcare AI from prototype to production: use-case selection, data access, evaluation, human-in-the-loop design, monitoring, and governance under FDA, ONC HTI-1, and NIST AI RMF.Read more
- Healthcare Predictive AnalyticsEngineering predictive models for healthcare with leakage-free features, temporal validation, calibration, subgroup analysis, and source-attribute transparency.Read more
Discuss your healthcare engineering project
Tell us about the system, the integrations it depends on, and the constraints you are working within. A senior engineer will review it and reply with questions, not a sales script.